FE Environmental water and wastewater, unit by unit
Water and wastewater is tied for the largest area of the exam at 12–18 questions. It is the treatment plant from headworks to sludge: what each unit removes, how it is loaded and how its performance is computed.
Updated Oct 29, 2026 · Not affiliated with NCEES.
ExamFE Environmental
questions on the exam12–18
problems on this page18
areas in the specification15
Checked
What the area covers
What the specification lists, grouped seven ways:
Characteristics: physical, chemical and biological quality of water and wastewater, nutrients included.
Mass balance and loading rates: removal efficiencies through a train of units.
Physical processes: sedimentation and clarification, filtration, adsorption and activated carbon, membranes, flocculation, headworks, flow equalization, air stripping.
Chemical processes: disinfection, ion exchange, softening, coagulation, precipitation.
Sludge: digestion, dewatering, composting, land application.
Water conservation and reuse.
18 treatment-plant problems, worked
0 / 18 answered · 0 correct
Question 1 of 18 · Water and Wastewater · 12–18 items
A plant with Q = 10,000 m3/day has influent BOD 200 mg/L and effluent BOD 20 mg/L. Yield Y = 0.50 g biomass/g substrate. The aeration basin mixed liquor contains X = 3,000 mg/L, and the basin volume is V = 5,000 m3. Endogenous decay b = 0.05 day−1. Calculate the net daily sludge (biomass) production (kg/day).
Given
Flow Q = 10,000 m3/day
Influent BOD = 200 mg/L
Effluent BOD = 20 mg/L
Yield Y = 0.50 g biomass/g substrate
MLSS X = 3000 mg/L
Basin volume V = 5000 m3
Endogenous decay b = 0.05 day−1
Find
Net daily sludge production (kg/day)
Solution
Net biomass production = yield on substrate removed − endogenous decay (Water and wastewater: activated sludge).
900 kg/day is gross biomass growth; endogenous decay still has to be subtracted.
1,650 kg/day adds decay to growth; endogenous respiration consumes biomass.
1,800 kg/day is the BOD removed, not the biomass produced.
Question 2 of 18 · Water and Wastewater · 12–18 items
Unit Process
BOD Removal Efficiency
Primary Clarifier
35%
Secondary Treatment
85%
A wastewater treatment plant consists of a primary clarifier followed by an aeration basin and secondary clarifier. The plant receives a flow of 5.0 MGD with an influent BOD concentration of 200 mg/L. Based on the removal efficiencies provided in the table, what is the final effluent BOD concentration?
Given
Flow = 5.0 MGD
Influent BOD = 200 mg/L
Primary removal = 35 %
Secondary removal = 85 %
Find
Final effluent BOD (mg/L)
Solution
Removals in series multiply the fractions remaining (Water and wastewater: treatment trains).
Question 3 of 18 · Water and Wastewater · 12–18 items
A disinfection contact basin has a volume of 600 m3 and treats a peak flow of 180 m3/h. The basin has a baffling factor of 0.4. If the chlorine residual is maintained at 2.5 mg/L, what is the actual CT value achieved?
Given
Basin volume = 600 m3
Peak flow = 180 m3/h
Baffling factor = 0.4
Chlorine residual = 2.5 mg/L
Find
Actual CT (mg·min/L)
Solution
CT credit uses the T10 contact time (Water treatment: disinfection).
500 uses the theoretical detention time (200 min); CT credit uses T10, which accounts for short-circuiting.
1,250 divides by the baffling factor instead of multiplying.
Question 4 of 18 · Water and Wastewater · 12–18 items
Stream
Flow (MGD)
TSS (mg/L)
Influent
5.0
200
Effluent
4.95
15
Waste Sludge (WAS)
0.05
8,000
Aeration Basin (MLSS)
-
3,000
Calculate the Solids Retention Time (SRT) for the activated sludge system described by the operational data in the table. The aeration basin volume is 2.0 MG.
Given
Aeration basin volume = 2.0 MG
MLSS = 3,000 mg/L
WAS flow = 0.05 MGD at 8,000 mg/L
Effluent flow = 4.95 MGD at 15 mg/L
Find
SRT (d)
Solution
SRT = solids in the reactor ÷ solids leaving per day (wasted + effluent) (Water and wastewater: activated sludge).
15.0 days counts only the waste sludge and ignores the 619 lb/d of solids lost in the effluent.
40.0 days divides the basin volume by the WAS flow, ignoring the concentrations.
Question 5 of 18 · Water and Wastewater · 12–18 items
A high-rate anaerobic digester is modeled as a CSTR. At 35 °C, volatile solids (VS) destruction follows first-order kinetics with k = 0.21 d−1, and the hydraulic retention time is 15 days. If the temperature drops to 20 °C, what is the expected percent VS destruction? Use a temperature coefficient θ = 1.08.
Given
Rate constant at 35 °C k = 0.21 d−1
Hydraulic retention time = 15 days
New temperature = 20 °C
Temperature coefficient θ = 1.08
Find
Percent VS destruction at 20 °C (%)
Solution
Temperature-correct k, then apply the CSTR first-order removal (Water and wastewater: anaerobic digestion).
63.0% applies the plug-flow form 1 − e−kτ; the digester is a completely mixed reactor.
75.9% is the destruction at 35 °C; the rate must be corrected to 20 °C first.
90.9% applies θ with the wrong sign (1.08+15), raising k as the temperature falls.
95.7% uses the 35 °C rate and the plug-flow form, two errors at once.
Question 6 of 18 · Water and Wastewater · 12–18 items
An activated sludge aeration basin is designed with a maximum specific growth rate for nitrifiers of μmax = 0.8 d−1. The half-saturation constant for dissolved oxygen (DO) is KDO = 1.5 mg L−1. If the basin is operating with a DO concentration of 0.5 mg/L, what is the specific growth rate due to oxygen limitation?
Given
μmax = 0.8 d−1
KDO = 1.5 mg/L
DO = 0.5 mg/L
Find
Specific growth rate (d−1)
Solution
Monod (switching) function for dissolved oxygen (Water and wastewater: nitrification kinetics).
Question 7 of 18 · Water and Wastewater · 12–18 items
A water treatment plant processes 15 MGD (56.8 MLD). Jar tests indicate an optimal ferric chloride dose of 25 mg/L. The plant uses a stock solution with the properties listed below. Calculate the required feed pump setting.
Property
Value
Stock Strength
40% by weight
Specific Gravity
1.45
Active Chemical
Ferric Chloride
Given
Plant flow = 15 MGD (56.8 MLD)
Ferric chloride dose = 25 mg/L
Stock strength = 40% by weight
Stock specific gravity = 1.45
Find
Feed pump setting (L/min)
Solution
Chemical feed = dose × flow ÷ (solution strength × density) (Water treatment: chemical feed).
2.5 L/min uses the 40% strength but leaves out the specific gravity of 1.45.
2,400 is the feed in L/day; it was not converted to L/min.
Question 8 of 18 · Water and Wastewater · 12–18 items
A GAC contactor treats a waste stream containing 100 µg/L of PCE. The adsorption follows a Langmuir isotherm with qmax = 50 mg/g and K = 0.5 L/mg. If the contactor contains 10,000 kg of carbon and treats 2 MLD, estimate the bed life until saturation (assume the entire bed reaches equilibrium with the influent).
Given
Influent PCE = 100 µg/L
qmax = 50 mg/g
Langmuir K = 0.5 L/mg
Carbon mass = 10,000 kg
Flow = 2 MLD
Find
Bed life (d)
Solution
Bed life = equilibrium capacity at the influent concentration ÷ daily loading (Water treatment: adsorption).
0.119 days treats q as mg per kg of carbon instead of mg per g.
Question 9 of 18 · Water and Wastewater · 12–18 items
Operational data for a membrane filtration system is shown below. Water viscosity is 1.00 cP at 20°C and 1.31 cP at 10°C. Evaluate the condition of the membrane at Day 30.
Parameter
Day 1
Day 30
Flux (LMH)
40
30
TMP (bar)
0.4
0.5
Temperature (°C)
20
10
Given
Day 1: flux 40 LMH, TMP 0.4 bar, 20 °C
Day 30: flux 30 LMH, TMP 0.5 bar, 10 °C
Viscosity = 1.00 cP at 20 °C
Viscosity = 1.31 cP at 10 °C
Find
Membrane condition at day 30
Solution
Compare temperature-corrected specific flux (permeability) (Water treatment: membranes).
day 1: 40/0.4 = 100 LMH/bar; day 30: (30/0.5) × (1.31/1.00) = 78.6 LMH/bar → 21% decline
Raw flux fell partly because cold water is more viscous, but even after correcting to 20 °C the permeability is 21% lower.
Temperature-corrected permeability fell from 40/0.4 = 100 to (30/0.5) × 1.31 = 78.6 LMH/bar, about 21% lower, which indicates fouling.
Both raw and temperature-corrected permeability are lower on day 30, so performance declined.
An integrity failure lets water bypass the membrane and raises permeability; the data show a decrease.
The data show a permeability loss but cannot tell whether cleaning would recover it, so irreversibility cannot be concluded.
Question 10 of 18 · Water and Wastewater · 12–18 items
A rapid sand filter operates with a hydraulic loading rate of 12 m/h. The clean bed headloss is 0.5 m, and the maximum allowable headloss is 2.5 m. Headloss accumulates at 0.04 m/h. Turbidity breakthrough consistently occurs at 40 hours. Determine the filter run time and the limiting factor.
Given
Hydraulic loading rate = 12 m/h
Clean bed headloss = 0.5 m
Maximum headloss = 2.5 m
Headloss accumulation = 0.04 m/h
Turbidity breakthrough = 40 h
Find
Filter run time and limiting factor
Solution
A filter run ends at whichever limit comes first (Water treatment: filtration).
Turbidity breaks through at 40 hr, not 50 hr; 50 hr is the headloss time.
50 hr is when headloss would reach 2.5 m, but the filter has already broken through at 40 hr.
62 hr divides the full 2.5 m by 0.04 m/hr and forgets the 0.5 m clean-bed headloss.
Terminal headloss would be reached after (2.5 − 0.5)/0.04 = 50 hr, but turbidity breaks through at 40 hr, so turbidity ends the run.
The run length is right, but at 40 hr the headloss is only 0.5 + 1.6 = 2.1 m, below the 2.5 m limit.
Question 11 of 18 · Water and Wastewater · 12–18 items
Adsorption data for a contaminant follows the Freundlich isotherm qe = Kf Ce1/n. Experimental results show that when Ce = 1 mg/L, qe = 10 mg/g; and when Ce = 100 mg/L, qe = 100 mg/g. Determine the isotherm equation.
Given
qe = 10 mg/g at Ce = 1 mg/L
qe = 100 mg/g at Ce = 100 mg/L
Find
Freundlich isotherm equation
Solution
Fit both constants from two points; log q = log Kf + (1/n)log C (Water treatment: adsorption isotherms).
Dropping Kf gives qe = 1 at Ce = 1, not the measured 10 mg/g.
At Ce = 1, qe = Kf = 10; then 100 = 10 × 1001/n gives 1001/n = 10, so 1/n = 0.5.
2.0 is n, not 1/n; the exponent in the isotherm is 1/n = 0.5.
An exponent of 1.0 would give qe = 1,000 mg/g at Ce = 100, not 100.
Kf is qe at Ce = 1 mg/L, which is 10, not 100.
Question 12 of 18 · Water and Wastewater · 12–18 items
A membrane plant requires a total permeate production of 2.4 MLD. The design flux is 20 L/(m2·h). If each membrane module has a surface area of 25 m2, how many modules are required?
Given
Permeate production = 2.4 MLD
Design flux = 20 L/(m2·h)
Module area = 25 m2
Find
Number of modules
Solution
Area = flow ÷ flux, then divide by module area (Water treatment: membranes).
Q = 2.4 × 106 L/d ÷ 24 h/d = 1.0 × 105 L/h
A = 1.0 × 105/20 = 5,000 m2; N = 5,000/25 = 200 modules
8 modules divides by 24 a second time after the flow is already in L/hr.
250 divides the 5,000 m2 area by the flux (20) instead of the module area (25 m2).
4,800 leaves the flow in L/d while the flux is in L/(m2·h), a factor of 24.
5,000 is the membrane area in m2, not the number of modules.
Question 13 of 18 · Water and Wastewater · 12–18 items
A rectangular grit chamber is designed with a cross-sectional area of 1.0 m² and handles a peak flow of 0.6 m³/s. The detention time is 45 seconds. Evaluate the hydraulic design with respect to grit scour.
Given
Cross-sectional area = 1.0 m2
Peak flow = 0.6 m3/s
Detention time = 45 s
Find
Assessment of the hydraulic design
Solution
Horizontal velocity controls grit removal: about 0.3 m/s settles grit while keeping organics in suspension (Wastewater: preliminary treatment).
vh = Q/A = 0.6 m3/s ÷ 1.0 m2 = 0.6 m/s > ≈ 0.3 m/s
No depth criterion is violated by the data; the problem shows up in the velocity.
Low velocity would let organics settle with the grit; here the velocity is too high.
The 45 s detention is typical, but the horizontal velocity of 0.6 m/s is far above the target.
Peak-flow detention of 45 to 90 s is common for grit chambers; 45 s is not the problem.
v = Q/A = 0.6/1.0 = 0.6 m/s, about twice the roughly 0.3 m/s used for grit chambers, so settled grit would be scoured back out.
Question 14 of 18 · Water and Wastewater · 12–18 items
A granular activated carbon (GAC) contactor is designed to treat 1.5 MGD of groundwater containing 20 mg/L of TOC. The theoretical equilibrium adsorption capacity (qe) at this concentration is 25 mg TOC per gram of GAC. To account for the mass transfer zone and early breakthrough, the design usage rate is based on 40% of the theoretical equilibrium capacity. Calculate the daily GAC consumption rate.
Question 15 of 18 · Water and Wastewater · 12–18 items
For an activated sludge system with μmax = 0.6 d−1, Ks = 20 mg/L, X = 3,000 mg/L, Y = 0.5 mg VSS/mg substrate, and substrate concentration S = 5 mg/L, compare the substrate removal rates predicted by the full Monod model and by the first-order approximation (valid for S ≪ Ks). Report the two rates as Monod, then first-order.
Given
μmax = 0.6 d−1
Ks = 20 mg/L
X = 3,000 mg/L
Y = 0.5 mg VSS/mg S
S = 5 mg/L
Find
Substrate removal rates, Monod and first-order (mg/(L·d))
Solution
Monod substrate use r = μmaxSX/[Y(Ks + S)]; the first-order form drops S from the denominator (Water and wastewater: kinetics).
Monod: μ = 0.6 × 5/25 = 0.12 d−1, r = 0.12 × 3,000/0.5 = 720; first-order drops S from the denominator: 0.6 × 3,000 × 5/(20 × 0.5) = 900.
The first-order form uses Ks alone in the denominator, so it cannot equal the Monod rate when S = 5 mg/L is not negligible.
The values are reversed: the full Monod rate is the lower one, 720.
360 and 450 leave out the yield; rs = μX/Y.
180 and 225 multiply by Y instead of dividing; substrate use is growth divided by yield.
Question 16 of 18 · Water and Wastewater · 12–18 items
A wastewater influent contains NH4-N = 35 mg/L. During nitrification, 90% of the NH4-N is oxidized to NO3-N. Nitrification consumes 7.14 mg alkalinity as CaCO3 per mg N oxidized. If the influent alkalinity is 250 mg/L as CaCO3, what is the residual alkalinity after nitrification?
475 mg/L adds the consumption to the influent alkalinity; nitrification destroys alkalinity.
225 mg/L is the alkalinity consumed, not what remains.
219 mg/L subtracts the 31.5 mg/L of nitrogen oxidized instead of the alkalinity it consumes (31.5 × 7.14).
138 mg/L uses 3.57 mg/mg, the alkalinity recovered by denitrification, instead of 7.14 consumed by nitrification.
N oxidized = 35 × 0.90 = 31.5 mg/L; alkalinity used = 31.5 × 7.14 = 225 mg/L; residual = 250 − 225 = 25 mg/L as CaCO3.
Question 17 of 18 · Water and Wastewater · 12–18 items
A wastewater stream (100 m3/d) contains 50 mg/L fluoride (F−). The plant requires effluent F− reduction to 5 mg/L using calcium chloride (CaCl2). Given Ksp for CaF2 is 4.0 × 10−11 and atomic weights Ca=40, Cl=35.5, F=19, what is the theoretical daily CaCl2 requirement?
Given
Flow = 100 m3/d
Influent F− = 50 mg/L
Effluent F− = 5 mg/L
Ksp of CaF2 = 4.0 × 10−11
Atomic weights Ca = 40, Cl = 35.5, F = 19
Find
Daily CaCl2 requirement (kg/d)
Solution
Calcium is consumed by CaF2 and an excess must stay dissolved to hold fluoride at the limit (Water and wastewater: chemical precipitation).
F− removed = 45 mg/L ÷ 19 g/mol = 2.37 × 10−3 M → Ca for CaF2 = 1.18 × 10−3 M
6.4 kg/d covers only the excess calcium that must stay dissolved (5.78 × 10−4 M) and forgets the calcium consumed by the precipitate.
13.1 kg/d is the stoichiometric calcium for 45 mg/L of fluoride; without the residual excess the effluent cannot be held at 5 mg/L.
Stoichiometric Ca = (45/19)/2 = 1.18 × 10−3 M; residual Ca = Ksp/[F−]2 = 5.78 × 10−4 M; total 1.76 × 10−3 M × 111 g/mol × 100 m3/d = 19.6 kg/d.
32.7 kg/d assigns one Ca2+ per F−; CaF2 needs one calcium for every two fluorides.
19,600 is the requirement in g/d; it was not converted to kilograms.
Question 18 of 18 · Water and Wastewater · 12–18 items
An MLE wastewater process treats 4.0 MGD with influent TKN of 30 mg/L. RAS flow is 2.0 MGD and internal recycle is 14.0 MGD. Assuming complete nitrification, complete denitrification capacity, and negligible biomass synthesis, calculate the effluent nitrate (NO3-N) concentration.
Given
Influent flow = 4.0 MGD
Influent TKN = 30 mg/L
RAS flow = 2.0 MGD
Internal recycle = 14.0 MGD
Find
Effluent NO3-N (mg/L)
Solution
MLE with complete nitrification and denitrification: only the nitrate not recycled to the anoxic zone leaves (Wastewater: nitrogen removal).
7.50 mg/L drops the 1 for the forward flow: 30/(0.5 + 3.5).
20.0 mg/L leaves out the internal recycle: 30/(1 + 0.5).
30.0 mg/L assumes no recycle reaches the anoxic zone, so none of the nitrate is denitrified.
Answer every question to see your score
Common traps
BOD5 is not ultimate BOD. The five-day test sees only part of the oxygen demand. With a base-e rate constant k in 1/day:
BOD5 = BODu (1 − e−5k)
A constant given in base 10 must be converted first: ke = 2.303 k10.
Overflow rate, detention time and weir loading are three different checks. The overflow rate Q/A is the settling velocity a clarifier captures, and it does not depend on depth. Detention time is V/Q. Weir loading is flow per length of effluent weir. A problem can pass one and fail another.
Hardness is reported as CaCO3. Convert each ion through its equivalent weight before adding: Ca2+ 20.0, Mg2+ 12.2 and CaCO3 50.0 g/eq. Carbonate hardness is the smaller of total hardness and alkalinity; only the noncarbonate part needs soda ash in lime-soda softening.
Loads in USCS: the mg/L × MGD × 8.34 = lb/day conversion is on exam facts. Handbook search terms for this area: BOD, overflow rate, hardness, activated sludge.
Water law in one line each
The ethics area includes compliance with environmental law, and for water two statutes cover it:
Clean Water Act (CWA): discharges to surface waters. A point source needs an NPDES permit (EPA summary).
Safe Drinking Water Act (SDWA): public drinking water. EPA sets maximum contaminant levels and treatment techniques (EPA summary).
How many water and wastewater questions are on the FE Environmental exam?
12–18 of 110, tied with fluid mechanics and hydraulics as the largest area.
Are regulations tested?
Yes, under ethics: the specification lists compliance with codes, standards and regulations and names the Clean Water Act and the Safe Drinking Water Act among its examples. Expect to know what a statute governs, not its section numbers.
Treatment problems on your phone
FE Environmental questions, answers and worked solutions in a study app.